Dried carp pituitary · 1 g vials · shipped worldwide
Technique

The interval is a temperature question, not a stopwatch

Two hatcheries can run the same material and the same dose and get their ovulation checks an hour or more apart, simply because their water is different. That is the single most common reason a copied schedule fails.

What latency actually depends on

Latency is the interval between the resolving injection and ovulation. In cyprinids it is temperature dependent: warmer water generally shortens it and cooler water lengthens it. It also varies with species, the stage of the females and the protocol in use. So there is no single number a supplier can honestly print on a spec sheet.

What matters practically is that the check schedule has to be built for your water on the day, using the interval your local hatchery authority recognises. The two-injection guide covers where the interval sits in the sequence, and the ovulation check guide covers what happens when the check is early or late.

Why I do not publish an hour table

An hour table would need to be right for your species, your temperature, your protocol and your population. I do not have verified figures covering that combination, and a plausible-looking table is worse than no table because people schedule staff against it. You will find the same refusal on our koi page and catfish page.

Use the published protocol for your species and region, then calibrate from your own logs. After three or four rounds you will have a better interval estimate for your farm than any supplier can give you.

What to log, every single round

The temperature record that makes the interval interpretable
WhenRecordWhy
At injectionWater temperature and actual clock timeThis is where the interval starts
During the intervalAny temperature swing, e.g. a cold top-up or a heat spikeExplains a round that ran late or early
At first checkActual clock time and observationPlanned times hide drift
At strippingTemperature, time, egg quality notesLinks the interval to the outcome
After the roundOne change to make next timeKeeps calibration to one variable

Log actual times, not the planned ones. A schedule that drifted by 40 minutes is only visible if both columns exist. The hypophysation sequence page has a compact round-record template covering the same fields plus lot number and dose basis.

Cold water and warm water are different problems

In cool water the interval lengthens, the cohort can become less synchronised, and staff may be tempted to check early. In warm water the window between ripe and overripe narrows, so a late check costs more. Neither case is fixed by changing the dose; both are fixed by moving the check schedule. We have short pages on both ends in other languages: cold water (RU) and warm water spawning (ES).

The troubleshooting page puts temperature alongside the other usual causes in the order worth checking, so you do not end up blaming the vial for a scheduling problem.

Where the dose record fits

Temperature and dose are separate variables and should stay separate in your notes. The dose comes from measured female biomass using the general 2–5 mg/kg working range; the interval comes from temperature and protocol. That is why the carp pituitary dosage page carries a temperature column next to the arithmetic rather than folding the two into one table.

If a round goes wrong, change one of them next time, not both. Otherwise the log cannot tell you which one mattered.

Planning staff around an uncertain window

Because the interval is not fixed, build a check rota with slack at both ends and have the stripping bench ready before the first check. If you need a guaranteed stripping hour for a fixed crew, a whole-gland preparation is the wrong tool; the Ovaprim comparison explains when I recommend a defined synthetic product instead.

Scope. No hour thresholds, degree-hour coefficients or species-specific latency values are given on this page because we do not hold verified figures for them. The only numeric ranges here are the general working range and pack details from our own product specification. Use the protocol of your local hatchery authority and calibrate from your own round records. The technical library indexes the published sources.

Questions I get asked

How many hours after injection should I check for ovulation?

Use the interval your local hatchery authority recognises for your species and water temperature. I do not publish an hour table because it would be wrong for most farms and people schedule staff against it.

Does a higher water temperature always mean a shorter latency?

Generally in cyprinids, but species, female stage and protocol also matter. Treat it as a direction for planning, not a formula, and log the actual times each round.

Should I change the dose when the water is cold?

Not on the basis of temperature alone. Keep dose and interval as separate variables in your records, and change one at a time on the next round.

Why does the dosage page have a temperature column?

Because the two pieces of information belong to the same round record but are not the same decision: dose comes from biomass, the check schedule comes from temperature and protocol.

What if my crew needs a guaranteed stripping hour?

Then consider a product with a defined latency instead of whole gland. The Ovaprim comparison page lists the cases where I recommend that.

Build the interval from your own water, not a table

Tell me your species, temperature range and current check schedule on WhatsApp. I will send the round-record fields and the current batch COA; the interval itself should come from your local protocol and your own logs.

Message Jeff on WhatsApp WhatsApp / phone: +86 186 2909 1156